60D5h, 68D5h Touch probe 1 positive edge counter - AxisX

A counter that is incremented with each rising edge of the touch probe 1 input.

The counter is only valid if the touch probe 1 is enabled (60B8h, bit 0 = 1b). When configured to capture only the first event only bit 0 changes. When configured for continuous triggering, the value is an unsigned 16-bit value with overflow.

See Touch Probes.

Axis 1

Parameter Index Sub-Index Data Type Float Scale Units Access PDO Mappable SMM Versions
Touch probe 1 positive edge counter - Axis 1 60D5h 0 Unsigned16 - - Read only Yes All

Axis 2

Parameter Index Sub-Index Data Type Float Scale Units Access PDO Mappable SMM Versions
Touch probe 1 positive edge counter - Axis 2 68D5h 0 Unsigned16 - - Read only Yes All